Fleetwood Enterprises Inc. has announced NHTSA recall 08V232000,
which affects some 2004 through 2006 Jamboree GT and Tioga SL 29 S
model motorhomes built from November 15, 2002, through June 10,
2005. The potential number of coaches involved is 135.
On affected
motorhomes, the black iron propane pipe located under the motorhome
may come in contact with chassis components during travel and, under
certain circumstances, become pinched or crushed. This could cause a
propane gas leak and potentially lead to an explosion or fire.
Dealers will inspect and relocate the black iron propane pipe, if
necessary. The total length of time the motorhome will be out of
service will depend on the dealer’s work schedule.
For more
information about this recall, contact Fleetwood at (800) 509-3418.
Owner notification was expected to begin in June 2008.
Ford Motor Company has announced NHTSA recall 08V165000, which
affects certain 2008 E-350 vehicles with a 138-inch wheelbase built
from September 1, 2007, through December 14, 2007. The potential
number of vehicles involved is 3,331.
On certain vehicles, used in
the production of type B and type C motorhomes, the driveshaft may
have been manufactured with a slip yoke that has cracks, which could
reduce fatigue performance below the design specifications. Cracks
in the slip yoke could progress over time, and the slip yoke could
crack without warning while the vehicle is being driven, allowing
the driveshaft to separate from the vehicle and increasing the risk
of a crash.
Dealers will inspect the driveshaft to determine its
manufacturing date and replace the driveshaft, if necessary. The
repair is expected to take four hours. However, because of service
scheduling times, the service center may need the vehicle for a
longer time period.
For more information about this recall,
contact Ford at (800) 392-3673. Owner notification began in April
2008.
Jayco Inc. has announced two separate NHTSA recalls.
The
first is recall 08V207000, which affects some 2005 through 2008
Seneca and 2007 and 2008 Greyhawk motorhomes built from July 20,
2004, through October 30, 2007. The potential number of coaches
involved is 1,164.
On certain motorhomes, the conduit clamp on the
copper LP-gas tube feeding the slideout is incorrectly placed, which
may allow the copper tube to bend and possibly leak with the
movement of the slideout. If the copper tube cracks, pressurized LP
gas may escape into the compartment. This condition could result in
a fire, injury, or death.
Dealers will relocate the conduit clamp
and add a rubber grommet to allow adhesion. The repair is expected
to take approximately one hour. However, because of service
scheduling times, the service center may need the vehicle for a
longer time period.
The second is recall 08V209000, which affects
some 2005 through 2008 Seneca motorhomes built from May 25, 2005,
through October 22, 2007. The potential number of coaches involved
is 1,673.
On certain motorhomes, an electrical short can occur if
the battery cables were not tucked into the battery compartment in a
manner that does not allow the cables to be pinched between the
battery slide tray and the compartment door. This condition could
result in a fire, injury, or death.
Dealers will relocate the
battery cables to the rear battery and reposition the P-clamp so as
not to allow the battery cable to become pinched. The repair is
expected to take approximately 30 minutes. However, because of
service scheduling times, the service center may need the vehicle
for a longer time period.
For more information about these
recalls, contact Jayco at (574) 825-5861. Owner notification for
both recalls was expected to begin in May 2008.
Norcold Inc. has
announced NHTSA recall 08E030000, which affects certain
refrigerators installed as original equipment in recreation
vehicles. The recall includes models 1200LR, 1200LRIM, and 1201LRIM,
manufactured from March 1, 1999, through February 28, 2001, with
cooling unit serial numbers between 1008701 and 1273700 (this is an
expansion of recall 02E045000). Norcold is working to identify the
total number of refrigerators that were manufactured with this
condition.
On affected units, a fatigue failure in the section of
the cooling unit that contains the refrigerant could allow the
liquid solution to slowly leak. If a leak occurs and the
refrigerator continues to operate after the solution circulation has
ceased, the heat source could generate very high temperatures. At
such high temperatures, the steel material of the cooling unit could
soften and rupture. If refrigerant gas is still in place when the
rupture occurs, hydrogen gas may be expelled and could be ignited by
the high temperature, possibly causing a fire.
Norcold is working
with the RV manufacturers to notify owners and repair the cooling
units.
For more information about this recall, contact Norcold
Inc. at (800) 767-9101. Information is also available at
www.norcold.com (select Customer Support, then Recall Info). Owner
notification for this recall was expected to begin in May 2008.